Search this site
77 results found with an empty search
- Froude Number: What It Is, Formula Fr = V/√(gD) & Calculator
Calculate the Froude number for open-channel flow with a worked example: Fr = V/√(g·D), subcritical, critical or supercritical flow and hydraulic jump type. Free. Froude number (Fr) The Froude number, Fr = V/√(g·D), compares inertia and gravity: Fr < 1 is subcritical flow, Fr = 1 critical and Fr > 1 supercritical. *Simplified calculation of local gravity. The Froude number is a fundamental dimensionless parameter in hydraulic studies, used to understand free surface (non-pressurized) flows. It is defined as the ratio of flow velocity to the propagation speed of gravity waves at the surface, or as the ratio of inertial forces to the local force of gravity. Its mathematical expression is: Where: - Fr: dimensionless Froude number. - v: average axial velocity of the fluid. - g: local gravity. - L: hydraulic depth of the channel. This number is used to determine whether the flow regime is subcritical, critical, or supercritical. Subcritical regime (Fr < 1): Characterized by low velocities and high depths, where gravity dominates the flow. Disturbances can propagate both upstream and downstream. Critical regime (Fr = 1): At this point, inertial and gravitational forces are balanced. The flow reaches the minimum specific energy for a given flow rate, and any disturbance can cause a transition to a regime. This phenomenon is precisely what is used for flow measurement in regime-changing gauges such as Parshall flumes or Long Throat Gauges (LTGs). Supercritical regime (Fr > 1) In this regime, the flow exhibits high velocities and low depths (normal behavior with increasing velocity), dominated by inertia. Disturbances only propagate downstream, which means that flow control must be achieved from upstream. When it is necessary to know the regime that exists in a channel or river without the need to take measurements, there is an empirical method used by hydraulic experts. This is important since to perform the gauging of a river, a Froude number < 0.6 is required, just as if a regime change gauging system is installed, it is required that before the control zone, a subcritical regime is had precisely so that when passing through the Parshall, AGL, etc., a regime change occurs to supercritical and the height at the critical depth can be measured and the flow circulating in that river can be known. Therefore, the method known as putting the stick in consists of putting a stick into the river and checking the behavior of the waves that are generated as in the following image: With enough experience, you will be able to empirically determine the approximate Froude number without having a level and speed meter at hand. Worked example Rectangular channel with mean velocity v = 1.20 m/s, flow depth y = 0.50 m and g = 9.80665 m/s²: Fr = 1.20 / √(9.80665 × 0.50) = 1.20 / 2.214 = 0.54 Since Fr < 1, the flow is subcritical. If the same channel carries v = 3.00 m/s at a depth of 0.25 m, √(9.80665 × 0.25) = 1.566 m/s and Fr = 3.00 / 1.566 = 1.92: the flow is supercritical. Non-rectangular channels: hydraulic depth In trapezoidal or circular channels, L is not the flow depth but the hydraulic depth D = A / T (wetted area divided by top width). Example: trapezoidal channel with bottom width b = 2.0 m, side slope z = 1.5 and depth y = 0.80 m carrying Q = 3.0 m³/s: A = (b + z·y)·y = 2.56 m² T = b + 2·z·y = 4.40 m D = A / T = 0.582 m v = Q / A = 1.172 m/s Fr = 1.172 / √(9.80665 × 0.582) = 0.49 (subcritical) Hydraulic jump type by upstream Froude number Fr 1.0 to 1.7: undular jump Fr 1.7 to 2.5: weak jump Fr 2.5 to 4.5: oscillating jump Fr 4.5 to 9.0: steady jump, best energy dissipation Fr above 9.0: strong jump Frequently asked questions Which value of g should I use? 9.80665 m/s² is standard gravity. Local gravity ranges from about 9.78 to 9.83 m/s² depending on latitude and altitude (you can compute it with the local gravity calculator on this page). In the first example, using 9.78 changes Fr from 0.542 to 0.543, so the effect is small. What is critical depth? It is the depth at which Fr = 1. In a rectangular channel it equals yc = (q² / g)^(1/3), where q is the flow rate per metre of width. In the first example, q = 0.60 m²/s and yc = 0.33 m; since the actual depth (0.50 m) is larger, the flow is subcritical. Does the Froude number depend on viscosity? No. Viscous effects are described by the Reynolds number ; the Froude number compares inertia with gravity and governs free-surface flows. At Axotek, we listen to our users. If you need a calculator to make your work and/or projects easier, you can contact us, and as soon as possible, we'll have it online at no cost to you. Request calculator
- Politica de Privacidad | AxoTek
Visita nuestra Politica de Privacidad en AxoTek y AxoMex Privacy Policy PRIVACY POLICY. This Privacy Policy establishes the terms under which AxoTek.me uses and protects the information provided by its users when using its website. This company is committed to the security of its users' data. When we ask you to fill in the fields of personal information with which you can be identified, we do so ensuring that it will only be used in accordance with the terms of this document. However, this Privacy Policy may change over time or be updated, so we recommend and emphasize that you continually review this page to ensure that you agree with such changes. Information that is collected. Our website may collect personal information such as: Name, contact information such as your email address and demographic information. Likewise, when necessary, specific information may be required to process an order or make a delivery or billing. Use of the information collected. Our website uses the information in order to provide the best possible service, particularly to maintain a record of users, orders if applicable, and improve our products and services. Periodic emails may be sent through our site with special offers, new products and other advertising information that we consider relevant to you or that may provide you with some benefit, these emails will be sent to the address you provide and may be canceled at any time. AxoTek.me is highly committed to fulfilling the commitment to keep your information safe. We use the most advanced systems and constantly update them to ensure that there is no unauthorized access. Cookies A cookie refers to a file that is sent with the purpose of requesting permission to be stored on your computer, by accepting said file it is created and the cookie then serves to have information regarding web traffic, and also facilitate future visits to a recurring website. Another function that cookies have is that with them the websites can recognize you individually and therefore provide you with the best personalized service on your website. Our website uses cookies to identify which pages are visited and how often. This information is used only for statistical analysis and then the information is permanently deleted. You can delete cookies at any time from your computer. However, cookies help to provide a better service to websites; they do not give access to information about you or your computer, unless you want this and provide it directly. You can accept or deny the use of cookies, however most browsers automatically accept cookies as it helps to have a better web service. You can also change the configuration of your computer to reject cookies. If you decline them, you may not be able to use some of our services. Links to Third Parties This website may contain links to other sites that may be of interest to you. Once you click on these links and leave our page, we no longer have control over the site to which you are redirected and therefore we are not responsible for the terms or privacy or the protection of your data on those other third party sites. These sites are subject to their own privacy policies, so it is recommended that you consult them to confirm that you agree with them. Control of your personal information At any time you can restrict the collection or use of the personal information that is provided to our website. Each time you are asked to fill out a form, such as the user registration form, you can check or uncheck the option to receive information by email. If you have checked the option to receive our newsletter or advertising, you can cancel it at any time. This company will not sell, assign or distribute the personal information that is collected without your consent, unless required by a judge with a court order. We reserve the right to change the terms of this Privacy Policy at any time. Go back
- What Is My IP? – Public IP Address Lookup
Find your public IP address instantly, plus location, ISP and network details. Free IP lookup tool. IP Finder Discover your public and private IP address instantly. Our advanced network tool provides geolocation information, Internet Service Provider (ISP), ASN, time zone, and more. Query any IP manually and get accurate data quickly and easily. What exactly is an IP address? An IP address is a series of numbers separated by periods (such as 192.168.1.1 or 8.8.8.8) that acts as your device's postal address on the vast internet. Without it, the websites you visit wouldn't know where to send the information you request, your emails would get lost, and you wouldn't be able to stream videos. It's essential to understand that there are two main types of IP addresses that work together: 1. Public IP: Your Address to the World The public IP is the main address assigned to you by your Internet Service Provider (ISP). It represents your entire home or office network to the rest of the internet. It's Unique: No two networks in the world can have the same public IP address. Identify Your Network: All devices connected to your router (computers, phones, consoles) access the internet using this same public IP address. Reveals General Information: As you've seen in the tool, your public IP address can be used to determine your approximate geographic location (country, city), your Internet Service Provider (ISP), and other network information. Analogy: Think of the public IP address as the address of an apartment building. All mail from outside arrives at that single address. 2. Private IP: Your Apartment Number The private IP address is the address your router assigns to each device that connects to it within your local network. It's Not Globally Unique: Many networks around the world use the same range of private IP addresses (such as 192.168.x.x or 10.0.x.x). They only need to be unique within your own network. Identifies Your Devices Internally: Lets your router know which specific device (your phone, your laptop) to send information coming from the internet to. Not Visible on the Internet: No one outside your local network can directly see or access your private IP addresses. Analogy: Continuing with the example, the Private IP address is your apartment or door number. Once mail arrives at the building (the public IP address), the router (the concierge) needs to know which apartment (private IP address) to deliver it to. What Are IP Addresses Used For? Their main function is to ensure that data traffic reaches its correct destination, but this involves several key processes: Routing: IP addresses allow routers and servers around the world to know the best path to send data packets so that they reach their destination. Identification: They uniquely identify a device or network on the internet. Geolocation: They allow online services to offer content relevant to your location, such as showing you the local weather, news from your region, or results in your language. Access Control: Websites and services can use IP addresses to allow or block access from certain regions or networks. When you visit a website (e.g., google.com), your device sends a request to a DNS server (which translates the domain name into an IP address, such as 142.250.190.46). Your router (using its public IP address) then routes the request across the internet to the destination server, enabling communication. Importance of IP Addresses They facilitate data routing on the internet. They allow the configuration of private networks (LANs). They are essential for online services, gaming, streaming, and more. Problems and Future IPv4 address exhaustion drove the adoption of IPv6, which offers greater security and efficiency. Additionally, tools like NAT (Network Address Translation) allow multiple devices to share a public IP address. In short, IP addresses are the "digital ID" of devices, enabling the global interconnection that defines the digital age.
- Free Engineering & Metrology Calculators
Free engineering and metrology calculators: Reynolds, Froude, Parshall flume, water and air density, RTD, 4-20 mA, uncertainty and more. Calculators If you work with numbers, we can make your projects easier. We're always adding new calculators, and if you'd like us to add one, feel free to share your requests with us via email or in the Contact section. HOME Calculators Water Density Calculator Local Gravity Calculator Process Calculator (4 to 20) mA Froude No. Calculator Speed of Sound in Water Calculator Strouhal No. Calculator Area-Velocity Calculator Parshall canal calculator Catapult Simulation Calculator Parshall Constants Calculator Reynolds Number Calculator Speed Profile Correction Simple Calculator Battery Capacity Calculator RTD Resistance to Temperature Calculator Dew point calculator Calculator distance between coordinates interpolation extrapolation calculator Natural gas density calculator LPG Vaporization and Entropy CIMP Air Density Calculator Error Calculator Orbital escape velocity calculator Linear and Polynomial Regression Bullet Tank Volume Calculator Hydraulic Head Calculator Utilities QR code generator IP Finder IPFNA Pattern Selection Burnout Test life expectancy Coversores Pressure Unit Converter Temperature Unit Converter Flow Unit Converter Mass Flow Unit Converter Volume Unit Converter Mass Unit Converter Unit Converter Length Angle Unit Converter Storage unit converter Area Unit Converter Battery Energy Unit Converter Spreadsheets Informative Topics Speed Profile Correction What is Metrology? What is Uncertainty? What is ModBus? Reynolds Number in Flow News 1 About Us Contact Request... Name* Last name* E-mail* Application* Request
- Temperature Converter – °C, °F, K, °R
Convert temperature between Celsius, Fahrenheit, Kelvin and Rankine instantly. Free online temperature unit converter. Temperature Unit Converter Temperature, that intangible quality that determines everything from the weather to chemical reactions in our bodies, has been an object of scientific fascination for millennia. Its study represents one of humanity's most significant intellectual endeavors, one that intertwines physics, philosophy, and technological ingenuity. Temperature, in its purest form, is a measure of the average kinetic energy of the particles that make up a substance. This microscopic definition is expressed mathematically as: Where: ⟨Ek⟩ = average kinetic energy per particle kB = Boltzmann constant (1.380649 × 10⁻²³ J/K) T = absolute temperature in Kelvin This fundamental relationship connects the observable world with the quantum realm, revealing that what we perceive as "heat" is actually the frantic dance of atoms and molecules. In temperature, everything starts from absolute zero: The concept of absolute zero (-273.15°C or 0 K) is not merely a mathematical convention, but a physical limit imposed by the laws of thermodynamics. The third law formally states: Where S represents the entropy of the system and S₀ its value in the ground state, in practice, this principle implies that reaching absolute zero is impossible, although modern laser cooling techniques have achieved nanokelvin temperatures, approaching this cosmic limit. The path to precise temperature measurement began with qualitative devices such as Galileo's thermoscope (1592), which lacked a numerical scale. The major innovation came with liquid-in-glass thermometers, whose operation is based on the thermal expansion equation Where: ΔV = volume change V₀ = initial volume β = coefficient of thermal expansion ΔT = temperature change Later, more robust and specialized sensors were developed for each specific situation, for example: Thermocouples: These work through the Seebeck effect, which is the union of two different metals. The most common are type K (chromel-alumel) and type J (iron-constantan). When subjected to temperature changes, they generate an electrical potential difference. These sensors are very robust, have a long measuring range, are inexpensive, and have a very fast response time. However, their disadvantage is that this potential difference is not linear, and their accuracy is not very good. RTDs: They work through a thermoresistive effect, it is an electrical resistance that increases its value in ohms (Ω) as its temperature increases. They exist in various materials, the most common is platinum (PT100), which indicates that it has a resistance of 100 Ω at 0 ° C, but it can also be PT1000, which has 1000 Ω at 0 ° C. This value can be measured and is known as R₀. They exist in different classes and different sensitivities. They can be very precise if they are calibrated through characterization by the Callendar Van Dusen method or the ITS-90 method, in which the behavior of the resistance vs. temperature is obtained through coefficients that are entered into some industrial and scientific readers. Their disadvantages are that they have limited ranges at high temperatures, normally and commercially they only measure up to 660 ° C, they are slow to take the measurement (stabilize), and they are very prone to corrosion. They can crack and stop measuring due to thermal stress (going from low to high temperatures in a short period of time). Even in recent years, infrared thermography (pyrometers and thermal cameras) has gained significant importance due to its ability to measure in hostile or high-temperature environments, thus avoiding contact temperature measurements and preventing damage or accidents. This technology measures the temperature of an object by detecting the infrared radiation it emits, based on the Stefan-Boltzmann law. This technology has advanced significantly since the invention of the bolometer around 1880 by Samuel Pierpont Langley, and with thermal cameras, predictive maintenance can be performed and failures can be anticipated. In measuring thermal thermography, two terms normally arise: heat and temperature, which we explain: Heat is a form of energy in transit that flows spontaneously from warmer to colder bodies. Its study revolutionized science in the 19th century with the development of thermodynamics: Molecular kinetic energy: Heat manifests as the disordered motion of atoms and molecules (kinetic theory) First Law of Thermodynamics: ΔU = Q - W, where heat (Q) contributes to the internal energy (U) and W represents the thermodynamic work performed by the system on its environment. Transmission methods: Conduction (solids), convection (fluids), and radiation (vacuum) Temperature is a measure of the average kinetic energy of particles. Understanding it took centuries of development: • Historical scales: From the arbitrary degrees of Fahrenheit (1724) to the absolute Kelvin scale (1854) • Absolute zero (-273.15°C): Thermodynamic limit where molecular motion ceases • Instrumentation: Evolution from Galileo's thermoscopes to modern optical pyrometers. To measure temperature, we use different reference scales, each with its own characteristics and applications. For example: Celsius (°C) Definition: Based on the melting (0°C) and boiling (100°C) points of water at 1 atm. Usage: Metric system, science, and everyday life in most of the world. Incidentally, in some places, the scale is still called degrees Celsius. However, metrologically, this term has been obsolete since 1948, when the General Conference on Weights and Measures (CGPM) changed it to avoid confusion with the term angular unit (1/100 of a degree). Conversion formula: Kelvin (K) Definition: Absolute scale where 0 K = -273.15°C (absolute zero, absence of molecular motion). Use: Thermodynamics, quantum physics, and astronomy. Conversion formula: Fahrenheit (°F) Definition: Originally based on a mixture of ice, water, and sal ammoniac (0°F) and human body temperature (~96°F, later adjusted to 98.6°F). Use: Primarily in the U.S. and some English-speaking countries. Conversion formula: Rankine (°R) Definition: Absolute scale based on Fahrenheit (0°R = -459.67°F = absolute zero). Use: Thermal engineering in English systems. Conversion formula: Temperature scales are tools for translating human experience into the laws of physics. Their diversity reflects both historical and technical needs, but they all converge on one principle: quantifying thermal energy, from the most extreme cold in the universe to the intense heat of stars. Conversion table −40 °C = −40 °F = 233.15 K = 419.67 °R 0 °C = 32 °F = 273.15 K = 491.67 °R 20 °C = 68 °F = 293.15 K = 527.67 °R 37 °C = 98.6 °F = 310.15 K = 558.27 °R 100 °C = 212 °F = 373.15 K = 671.67 °R Frequently asked questions How do I convert a temperature difference? A difference does not include the 32 or 273.15 offset: 1 K = 1 °C and 1 °C = 1.8 °F. For example, an uncertainty of ±0.5 °C equals ±0.9 °F, not 32.9 °F. At what temperature are Celsius and Fahrenheit equal? At −40: −40 °C = −40 °F. What is ITS-90? The International Temperature Scale of 1990, the reference used by calibration laboratories. It defines fixed points (such as the triple point of water, 273.16 K) and interpolating instruments such as platinum resistance thermometers. GO TO CONVERTERS...
- What is Modbus? RTU vs TCP, Registers and Excel Example (Mbaxp)
What Modbus is (RTU, ASCII and TCP), function codes, 40001 addressing, a frame with CRC and how to read a float. Free example to read a Modbus device from Excel with Mbaxp. What is Modbus? and a free Excel example Go to home From the noisy corners of an industrial plant to the quiet and minimalist interior of a laboratory, there is a language that is not heard, but speaks volumes: Modbus. It is the language of PLCs, sensors, and controllers, which communicate with each other to continue generating products, raw materials, medicines, etc. Modbus is an open industrial communication protocol developed in 1979 by Modicon (now Schneider Electric), designed to enable the transmission of information between electronic devices. Its main purpose is to facilitate communication between programmable logic controllers (PLCs), sensors, actuators, SCADA systems, and other industrial equipment. Its operating principle is one asks, one answers (Master-Slave). Key Features: Available Protocols: Modbus RTU (over RS-485): efficient and widely used in the field. Modbus ASCII: less common, more readable, but slower. Modbus TCP/IP: modern version for Ethernet networks. Common data types: Coils: Digital outputs. Discrete inputs: Digital inputs. Input registers: Read-only analog values. Holding registers: Variables that can be read or written. Standard functions: Reading and writing bits and words (16-bit registers). Diagnostics and basic remote control. But let's start from the beginning, and there's nothing more basic than knowing how it works and how it's classified: Modbus and the OSI pyramid The OSI (Open Systems Interconnection) pyramid is a reference model that divides network communication into seven layers, from the physical to the application: Physical layer Data link layer Network layer Transport layer Session layer Presentation layer Application layer Where is Modbus in the OSI pyramid? Modbus is a layer 7 protocol, the application layer. This means that Modbus defines the format and meaning of the messages sent and received to control and read industrial devices. However, Modbus does not define either the physical layer or the data link layer, which are responsible for the actual transmission of bits and managing communication in the physical medium. What does it mean that Modbus is not the physical layer? The physical layer refers to the physical transmission medium, for example: RS-232, RS-485, Ethernet, fiber optic cables, etc. Modbus can operate over different physical media. For example: Modbus RTU uses RS-485 or RS-232 as the physical layer and defines how to structure serial messages. Modbus TCP uses Ethernet (physical and data link layers) and TCP/IP (network and transport layers) to transmit its messages. Therefore, Modbus is not a standard for cables or electrical signals, but rather a protocol that sits on top of other layers so that devices can understand each other. This means that what truly defines the protocol is how it interprets the bits it reads from the different physical layers, which in their basic structure are as follows: In Modbus, data types can be divided into two main types: coils and registers. Coils can be defined as digital, as they can only be ON (1) or OFF (0). Some coils can represent inputs, while others can represent outputs. Registers are 16 bits (2 bytes) unsigned and can therefore have values from 0 to 65535 (0 to FFFF). However, they have limitations, such as not being able to represent negative numbers, floating-point numbers, or values with representations greater than 65535. However, some manufacturers use two or more registers to create floating-point or negative numbers. Knowing that it's a Master-Slave-based protocol, how many devices can be connected to the network? The answer is... it depends. The standard limit is up to 32 devices total (1 master + 31 slaves), without repeaters, but let's analyze each possible scenario: Modbus ASCII (RS-232 or RS-485) With RS-232 (point-to-point): Only 2 devices (1 master and 1 slave). RS-232 is not multidrop, so it doesn't allow more than two devices. With RS-485 (as RTU): Same logic as RTU: up to 32 without repeaters, up to 247 with them. Modbus RTU (RS-485) Up to 32 devices total (1 master + 31 slaves), without repeaters. With RS-485 repeaters: You can reach up to 247 slaves, which is the logical limit of the Modbus protocol (addresses 1 to 247), if you use repeaters to regenerate the signal and increase the electrical fan-out. Modbus TCP/IP (Ethernet) Theoretically: The protocol uses IP addresses, so the practical limit is enormous. Unit ID: typically 1 to 247 (for compatibility with serial slaves through gateways). Number of nodes on the Ethernet network: depends on IP addressing, switches, routers, and traffic. In practice: You can have hundreds or thousands of devices, as long as the Ethernet network supports it. What's important: there is only one master per Modbus TCP connection, but there can be many simultaneous clients if the server/slave supports it. Modbus is a communications protocol, not a network topology per se. However, the way a Modbus network is physically connected, especially Modbus RTU over RS-485, typically adopts a daisy chain topology. A daisy chain network is a form of connection in which each device is connected in series to the next, forming a single communication line: That is: Master ─── > Slave 1 ─── > Slave 2 ─── > Slave 3 ───> Terminator Why does Modbus RTU use daisy chain? RS-485 is a half-duplex multidrop bus, allowing up to 32 devices to be connected on a shared line (with repeaters, up to 256 or more). RS-485 has a single differential line (A/B), and all devices must be connected in parallel, respecting the bus impedance. To avoid reflections, terminating resistors are placed at the ends of the chain. Although the physical connection looks like a direct line, in practical terms it is implemented as a chain—hence the name daisy chain—where the cable "hops" from slave to slave. And what about Modbus TCP? Modbus TCP/IP does not use daisy chain because it is based on Ethernet, which typically uses star (with switches) or mesh (in redundant industrial networks) topologies. In short, Modbus is an open and reliable standard, whose longevity demonstrates its effectiveness. It is the right choice when a simple, interoperable, and well-documented solution is needed for industrial communications. It also has a faster response time than, for example, HART, another industrial digital communication protocol. This makes it suitable for simple control systems that do not respond as quickly as temperature. Example: Sometimes it's very complex to read an article and learn simply from the theory, so at Axotek we've prepared an example that can be very useful in certain cases, such as the following: Imagine you arrive at the plant and find a Coriolis mass flow meter, which you need to know the total flow rate. But, surprise, the device is blind, meaning it doesn't have a display, but it does have a Modbus RTU 485 communication port. There are several ways to solve the problem: 1. Purchase the software from the manufacturer; this can be expensive in certain cases. 2. Search the internet for Modbus reading software such as Modbus Slave or Modbus Poll, but these are usually very complex if you're a beginner. 3. Download the Excel file we have at Axotek and modify it to your needs. For this last case, which is what we'll focus on, we'll need two files: an Excel file and an ActiveX library (OCX). ActiveX libraries are typically paid and licensed, but we'll use the one developed by Modbus Tools. The free version allows you to run for 60 minutes, and then you just need to restart the connection to have another 60 minutes. You can also purchase the paid version for unlimited access. Step 1: Download the two files: Download Modbus Excel Download Mbaxp You can also download Mbaxp from the official Modbus Tool website: https://www.modbustools.com/download.html There are several considerations regarding the files: - This only works with Windows operating systems. - When downloading, you must unzip the *.zip file. - In the case of Excel, it is an *.xlsm file, so it is an Excel file with macros; you must have them enabled. Also, when downloading the file, you must unzip it and right-click. In the General tab, select Unlock at the bottom. *Don't worry, you can scan it with your antivirus before or after unzipping.* 2: Once you have the two files (Excel and Mbaxp) the first thing required is to install the ActiveX library, then you just have to double click on the MBAXPSetup.exe file (choose 32 Bit or 64 Bit) and follow the instructions, once finished the window will close and you will be ready to open Excel. 3: Once installed, we proceed to open Excel, make sure you have the developer tab active, if it is not active in Excel Options > Customize Ribbon > and select Developer: We will base this practical example on how to visualize a Micro Motion CMF series Coriolis flowmeter, which has a Modbus output port. For this project, we need to display the following variables: - Instantaneous flow - Density - Temperature - Mass totalization And, additionally, the ability to reset the totalization to create batches. 4: We will download the Modbus mapping manual from the manufacturer's website and identify the variables we want to read and write, as well as the type of message to be sent. Remember that when installing Mbaxp, Excel becomes the Master and the device becomes the Slave. In the case of reading the variables, the manual states that they are Floating-point register pairs , so we will have two registers, each of which is RO = Read-only: -Flow: 247/248 RO -Density: 249/250 RO -Temperature: 251/252 RO -Total Mass: 259/260 RO So we must enter this information in this section of Excel in the "Inicio" workbook: You may be wondering why, if the flow addresses are 247/248, according to the manual, the addresses 246 are entered in Excel with a length of 2 (second green column). Well, this is because there are two ways to document Modbus registers: the logical address and the Modbus address, but what is each one? The logical address is a base-1 address, and it is widely used in manuals because it is more understandable to start at address 1. The Modbus address is the one with a base of 0; the registers are indexed from zero. That is: Holding Register 1 → address 0 (in the protocol). Also, in many documents, Holding Registers can be presented as 40001, 40002, 40247, etc. However, in actual Modbus transmission, the initial 4 (which indicates "holding register") is omitted and the output starts from 0. If you enter 2 in the second column (green), it means you are going to read two consecutive registers 246/247. The manual mentions that a coil must be activated to reset the totalizer, so we must write a coil. The manual specifies that it is number 3. Therefore, following the previous reasoning, we will enter number 2 in the "Write Coil" section. 5: Once we have researched and entered the data we will read and write, it is important to physically connect the device to the computer. This typically requires the use of a USB to RS485 converter: It can be any brand, and some are quite inexpensive. You just need to correctly install the manufacturer's drivers on your PC and know which COM port it's associated with. You'll also need to make the physical connection to the device according to its user manual: Remember that RS485 adapters can be 2 or 3 wires (A, B, and ground). In this case, we will use only one of the 2 wires, A and B. The A of the RS485 adapter must be connected to the A of the measuring device, and the B to the B. The following must also be configured: Baud Rate: Stop Bit: Parity: Data Bit: Slave ID: These data are usually included in the user manual, unless they have been modified. In this case, you should request these values from the person in charge of the equipment. For the COM port, you can view it in the PC's Device Manager: For the test we will do with a Micro Motion flowmeter, it is configured in Excel as follows: Once everything is configured, all that's left is to press the "Start Comm" button and that's it. A window will open informing you that you have 60 minutes left to use Modbus. When you press "Accept," a window will open showing the communication status. If the message does not appear, it means that you have blocked the ActiveX settings, you just need to enable them in the Excel Trust Center: If everything was done correctly, a window will open in which you can see the variables sent by the slave device and that you entered through the Modbus registers. You can also reset the total by pressing the "Reset Total" button. And with this, you'll be able to view the variables you need in real time. If you want to customize Excel for your project, it's also very simple. Just go to the "Developer" tab and then "See code." By opening the Forms section and then in UserForm1, you can modify the interface to your liking to make it fit your project: Remember that you can adapt this for any sensor, meter, or device that communicates via Modbus. It doesn't replace the manufacturer's software. This is for applications that need to be adapted to your needs. If you need to read or write other types of Modbus registers, the Mbaxp installation folder contains the code guide to do so: Modbus quick reference Most used function codes: 01 – Read Coils (digital outputs) 02 – Read Discrete Inputs (digital inputs) 03 – Read Holding Registers (read/write values, the most common) 04 – Read Input Registers (read-only values) 05 – Write Single Coil; 06 – Write Single Register 15 (0x0F) – Write Multiple Coils; 16 (0x10) – Write Multiple Registers Address map (base-1 notation used in manuals): 00001–09999 coils · 10001–19999 discrete inputs · 30001–39999 input registers · 40001–49999 holding registers. In the message the leading digit is dropped and counting starts at 0: 40001 travels as address 0, 40247 as 246. Example: a Modbus RTU frame, byte by byte Read 2 holding registers (40001–40002) from slave 1: 01 03 00 00 00 02 C4 0B 01 = slave ID · 03 = function · 00 00 = start address (40001) · 00 02 = number of registers · C4 0B = CRC-16 (low byte first). Slave response: 01 03 04 41 C8 00 00 6F F1 → 04 = byte count, 41 C8 00 00 = the data, 6F F1 = CRC. In Modbus TCP the same request has no CRC and starts with a 7-byte MBAP header: 00 01 00 00 00 06 01 03 00 00 00 02 (transaction 1, protocol 0, length 6, unit 1). Example: reading a 32-bit float from two registers A register holds 16 bits, so a float (IEEE 754) takes two. With the registers 41C8 and 0000 read in that order, the 32-bit word 0x41C80000 = 25.0 (for example 25 °C). Another example: 449A 5000 → 1234.5. If the value looks absurd (such as 2.36 × 10⁻⁴¹ instead of 25.0), the device sends the words in the opposite order (word swap): swap the two registers. Some devices also swap the bytes inside each word. Frequently asked questions What is Mbaxp? It is an ActiveX control (OCX) from Modbus Tools that lets Excel (VBA) act as a Modbus RTU/ASCII or TCP master. This example uses its free version, which runs for 60 minutes per connection. Why is the value I read off by one register? Because of base-1 vs base-0 addressing: register 40001 in the manual is address 0 in the message. If the device manual already lists base-0 addresses, do not subtract 1. What is the difference between Modbus RTU and Modbus TCP? RTU travels over RS-485/RS-232 in binary with a CRC and up to 247 slaves on one line; TCP travels over Ethernet, uses the MBAP header instead of a CRC and is addressed by IP plus a Unit ID. Why do I get no response from the device? Check, in this order: COM port, baud rate, parity, stop bits and slave ID; A and B wires (try swapping them); a 120 Ω termination resistor at the ends of long lines; and that only one master is polling the bus. We have more files and spreadsheets available: Download If you have any questions about a topic, ask us. Mail
- OrthoSmile | AxoTek
Software de administracion de consultorio dental
- Parshall Flume Constants (K and n) by Throat Width – Table & Examples
K and n constants of every standard Parshall flume size (Q = K·Hⁿ, metric), with worked examples, interpolation for other widths and free vs submerged flow limits. Parshall Constants Calculator The Concept of Deriving Parshall Channel Constants (C and m) The constants C and m for Parshall channels are not derived directly from theoretical principles of fluid mechanics for each channel size; instead, they are the result of an exhaustive process of experimental and empirical research. Important notes: Non-standard values: Values for W < 3" or 7.62 cm are theoretical extrapolations and are not supported by official standards. Parshall flumes for W < 3" are rare in practical applications due to accuracy limitations in low flow measurements. Values for W ≥ 3" were obtained from "JM De Azevedo and Guillermo Acosta (1976) Manual de Hidráulica" and from the Mexican standard "NMX-AA-179-SCFI-2018" Recommendation: If you need to use a Parshall flume for W < 3", consider performing an experimental calibration (secondary method) or using alternative technologies (such as triangular-crested weirs). What is a Parshall Flume? The Parshall flume, also known as a Parshall meter, is a hydraulic structure used to measure flow in open channels. It was developed by Ralph L. Parshall in the 1920s and has become a standard tool in hydraulic engineering due to its accuracy and ease of use. This device is characterized by its specific shape, which includes a convergent section, a narrow throat, and a divergent section, allowing the flow rate (Q) to be calculated from the depth measurement (h). Parshall Flume Constants and Flow Calculator Do you need to calculate the C and m constants for a Parshall flume? Or determine the flow rate Q quickly and accurately? Our Parshall Flume Constants Calculator is the perfect tool for you! With an intuitive and easy-to-use interface, this calculator allows you to: Calculate the constants C and m: Enter the throat width (W) and obtain the constants needed for the flow rate formula. Determine the flow rate (Q): Enter the hydraulic head (h) and calculate the flow rate in cubic meters per second (m3/s). Accurate results: Uses linear interpolation to get accurate values, even if the throat width does not match the values in the table. This tool is ideal for hydraulic engineers, students, and professionals working with Parshall flumes. Streamline your calculations and save time with our online calculator! Parshall flume constants (Q = K·Hⁿ, metric units) Q in m³/s, H (head measured in the convergent section) in meters. K is also written as C and n as m. Values used by the calculator, from W = 3" (0.0762 m): W = 0.0762 m → K = 0.176; n = 1.55 W = 0.152 m → K = 0.381; n = 1.58 W = 0.25 m → K = 0.561; n = 1.513 W = 0.3 m → K = 0.679; n = 1.521 W = 0.45 m → K = 1.038; n = 1.537 W = 0.6 m → K = 1.403; n = 1.548 W = 0.75 m → K = 1.772; n = 1.557 W = 0.9 m → K = 2.147; n = 1.565 W = 1 m → K = 2.397; n = 1.569 W = 1.2 m → K = 2.904; n = 1.577 W = 1.5 m → K = 3.668; n = 1.586 W = 1.8 m → K = 4.44; n = 1.593 W = 2.1 m → K = 5.222; n = 1.599 W = 2.4 m → K = 6.004; n = 1.605 W = 3.05 m → K = 7.463; n = 1.6 W = 3.66 m → K = 8.859; n = 1.6 W = 4.57 m → K = 10.96; n = 1.6 W = 6.1 m → K = 14.45; n = 1.6 W = 7.62 m → K = 17.94; n = 1.6 W = 9.14 m → K = 21.44; n = 1.6 W = 12.19 m → K = 28.43; n = 1.6 W = 15.24 m → K = 35.41; n = 1.6 Worked examples 1) 1 ft flume (W = 0.30 m) with H = 0.40 m: Q = 0.679 × 0.40^1.521 = 0.1685 m³/s = 168.5 L/s = 606.6 m³/h. 2) Throat not in the table (W = 0.35 m), H = 0.25 m: interpolate between 0.30 and 0.45 m. K = 0.679 + (0.05/0.15)(1.038 − 0.679) = 0.7987; n = 1.521 + (0.05/0.15)(1.537 − 1.521) = 1.5263. Q = 0.7987 × 0.25^1.5263 = 0.0963 m³/s (96.3 L/s). 3) Inverse: what head will 50 L/s give in the 0.30 m flume? H = (Q/K)^(1/n) = (0.050/0.679)^(1/1.521) = 0.180 m . Useful to choose the flume size: H should stay within the range of the level sensor. Frequently asked questions Where is the head H measured? In the converging section, at two-thirds of its length upstream of the throat (point Ha). The equation is only valid for free flow. When is the flow submerged? When the downstream level Hb rises and the ratio Hb/Ha exceeds about 0.5 for 1–3" flumes, 0.6 for 6–9", 0.7 for 1–8 ft and 0.8 for 10–50 ft. Above those limits Q = K·Hⁿ overestimates the flow and a submergence correction is needed. Can I use these constants with feet or inches? No. These K values are for meters and m³/s. With H in feet and Q in ft³/s the coefficients are different (for example Q = 4·W·H^(1.522·W^0.026) for 1–8 ft flumes). Why does the calculator interpolate? Standard flumes have fixed throat widths. If your flume does not match a size in the table, linear interpolation gives an approximate K and n; for billing or regulatory measurements it is better to calibrate the flume in place. To calculate flow only and learn more about Parshall visit our other resources: Parshall Calculator
- Escape Velocity & Orbital Velocity Calculator
Calculate escape velocity and orbital velocity for any planet or body. Enter mass, radius and altitude and get results instantly. Free. Escape Velocity Calculator Visit our menu for more articles and information... Everything in space is a delicate balance. A moving object, like a rocket or an asteroid, has inertia and wants to travel in a straight line forever. However, the immense gravitational force of a massive body (like a planet or a star) constantly attracts it, trying to make it fall. From the interaction between these two forces arise the fundamental concepts of orbital motion. What is Orbital Velocity? Orbital velocity (vorb) is the perfect "equilibrium point"—the exact speed at which an object must move laterally so that the curvature of its fall (caused by gravity) perfectly matches the curvature of the planet. Imagine you're on an incredibly tall tower and you fire a cannonball. If you fire slowly, it falls to Earth. If you fire faster, it travels farther before falling. If you fire at the exact orbital velocity, the cannonball "falls" perpetually, but the Earth curves "away" from it at the same rate. The cannonball never lands: it's now in orbit. It's in a constant state of free fall, but falling around the planet, not towards it. What is Escape Velocity? Now, what happens if you fire that cannonball even faster? Escape velocity (ve) is the point of no return; it is the minimum speed at which the object's kinetic energy is so great that the pull of gravity, although slowing it down, is never enough to stop it or change its path back. The object breaks its closed orbit and escapes the planet's gravitational "well," traveling indefinitely into deep space on an open trajectory (parabolic or hyperbolic). The Absolute Limit: Schwarzschild Radius Physics takes this concept to its most fascinating extreme. How dense would an object have to be for its escape velocity to equal the speed of light (the theoretical maximum speed in the universe)? The Schwarzschild radius (Rs) answers this question. It is the radius to which you would have to compress the entire mass of a body for its surface gravity to be so intense that not even light could escape. This is the threshold that defines the event horizon of a black hole. These three metrics are not just numbers; they are the principles that dictate how satellites orbit our world, how we send probes to other planets, and how we understand the most extreme objects in the cosmos. Formulas used by the calculator Orbital velocity: vorb = √( G·M / (R + h) ) Escape velocity: ve = √( 2·G·M / (R + h) ) = √2 · vorb Schwarzschild radius: Rs = 2·G·M / c² Where M is the mass of the body in kg, R its radius in m, h the altitude above the surface in m, G = 6.67430 × 10⁻¹¹ m³/(kg·s²) is the universal gravitational constant and c = 299,792,458 m/s is the speed of light. With h = 0 you get the values at the surface. Worked example: the International Space Station (ISS) Data: M = 5.972 × 10²⁴ kg (Earth), R = 6.371 × 10⁶ m, h = 408 km = 4.08 × 10⁵ m. 1. Distance to the center: r = R + h = 6.371 × 10⁶ + 4.08 × 10⁵ = 6.779 × 10⁶ m. 2. Product G·M = 6.67430 × 10⁻¹¹ × 5.972 × 10²⁴ = 3.986 × 10¹⁴ m³/s². 3. Orbital velocity: vorb = √(3.986 × 10¹⁴ / 6.779 × 10⁶) = 7,668 m/s = 7.668 km/s (about 27,600 km/h; the ISS circles the Earth every 92 minutes). 4. Escape velocity at that altitude: ve = √2 × 7.668 = 10.844 km/s. 5. Schwarzschild radius of the Earth: Rs = 2 × 3.986 × 10¹⁴ / (299,792,458)² = 8.87 × 10⁻³ m = 8.87 mm. The whole mass of the Earth would have to fit in a marble-sized sphere to become a black hole. Escape and orbital velocity at the surface of each body Moon: ve = 2.38 km/s · vorb = 1.68 km/s Mercury: ve = 4.25 km/s · vorb = 3.01 km/s Mars: ve = 5.03 km/s · vorb = 3.55 km/s Venus: ve = 10.36 km/s · vorb = 7.33 km/s Earth: ve = 11.19 km/s · vorb = 7.91 km/s Jupiter: ve = 60.20 km/s · vorb = 42.57 km/s Sun: ve = 617.77 km/s · vorb = 436.83 km/s Schwarzschild radius: Earth 8.87 mm, Jupiter 2.82 m, Sun 2.95 km. Frequently asked questions Why doesn't escape velocity depend on the mass of the rocket? Because kinetic energy (½·m·v²) and gravitational potential energy (G·M·m / r) are both proportional to the object's mass m; when you equate them, m cancels out. A pebble and a satellite need the same speed to escape. How are orbital velocity and escape velocity related? At the same distance from the center, escape velocity is always √2 ≈ 1.414 times the circular orbital velocity. Why do they decrease with altitude? Both depend on 1/√(R + h): the farther away you are, the weaker the pull. In geostationary orbit (h = 35,786 km) the orbital velocity is only 3.07 km/s and the escape velocity 4.35 km/s. Does a rocket have to reach 11.2 km/s to leave the Earth? Escape velocity is the speed needed by an object that receives no further thrust, ignoring air resistance. A rocket with its engines running could climb more slowly, but it would burn far more fuel; that is why missions gain that energy within a few minutes and above the dense atmosphere. What does the Schwarzschild radius represent? It is the radius of the event horizon: if all the mass of a body were squeezed inside that sphere, not even light could escape and the object would be a black hole. The formula for escape velocity is:
- About Us | AxoTek
Descubre quien esta detras de axotek.mey cual es nuestra mision en el mundo digital. About us: Who Are We? At axotek.me, we are a team passionate about technology, innovation, and knowledge. Founded in 2023, our project was born with the mission of expanding access to reliable, practical, and up-to-date technological information, aimed at people eager to learn through easy-to-use and well-explained articles and tools. Our Mission We believe that science and technology should be accessible, understandable, and useful to everyone. Therefore, we are dedicated to: - Researching, analyzing, and summarizing trends in technological and scientific tools, calculations, news, and documents. - Educating through guides, tutorials, documents, reviews, and tools that facilitate and streamline our users' tasks, all through well-documented information and years of experience in the field. - Inspiring our community so that, through our informative documents and digital tools, they can achieve their daily goals in their work, lives, and professional projects. Our Values ✔ Transparency: Documents and tools based on information confirmed and validated by people with experience in the field. ✔ Quality: Original content without additions so that the information is quickly assimilated. ✔ Innovation: Always at the forefront of the latest trends in the field. ✔ Community: We encourage interaction and collaborative learning, listening to and responding to our users' requests. The Team Behind Axotek.me We are a multidisciplinary team of: Engineers with experience in science and technology. Specialists in metrology, instrumentation, technology, chemistry, and biology. Founded by Eng. Ivan Ramirez Ledesma, who has over 12 years of experience in technological and scientific projects, specializing in the magnitudes of Flow, Mass, Pressure, Temperature, Volume, Humidity, Analytical Measurements, being accredited and signatory by Mexican accrediting entities, in addition to practical experience in metrological laboratories and industries such as Oil & Gas, Food, Beverages, Pharmaceuticals, Aeronautics. Go back
- Battery Energy Unit Converter | AxoTek
mAh to Wh calculator. Check if your power bank is suitable for air travel. Calculates conversions between mAh, Ah, Wh, and Joules by adjusting the voltage. Ideal for lithium batteries, USB drives, and car batteries. Battery Energy Unit Converter Battery power unit converters are fundamental tools in numerous technical fields and applications for several reasons; pressure unit converters play a fundamental role in standardization, accuracy, and efficiency in numerous technical and scientific fields, contributing significantly to interoperability and the advancement of global technology. Other Converters: -Pressure - Temperature - Flow
- Duda Emma | AxoTek
Coeficiente de sensibilidad tanque GST { "apiKey": "AIzaSyBIkk7QmZANAa--LkR9Y_tQo0g9vCj0-4k", "authDomain": "axotek-gst.firebaseapp.com", "projectId": "axotek-gst", "storageBucket": "axotek-gst.firebasestorage.app", "messagingSenderId": "146030753580", "appId": "1:146030753580:web:4be2191cf6557334319e89", "measurementId": "G-2YJL8E1KV2" }



