ACCREDITED CALIBRATION SERVICES

Calibration of Flow Meters, Tanks, Magnets and Gaussmeters

We check that your instruments measure what they claim to measure. We calibrate with standards traceable to CENAM (Mexico’s national metrology institute) and give you a calibration certificate accredited by EMA or PJLA.

Liquid flow  ·  Fixed and mobile tanks (tank trucks and rail tank cars)  ·  Gaussmeters and magnets

What we calibrate

The figures come from the official scope of each accreditation. If your instrument is not listed, ask us.

━━

Liquid flow

✔ ema accreditation FL-42

We check that your flow meter reads what actually passes through the pipe. We compare it, on your own line, against a Coriolis master meter calibrated at CENAM, and tell you how far off it is (error) and the factor to correct it (K-factor or meter factor).

 

For: industrial plants, fuel terminals and distribution, water utilities.

METERS

Coriolis (mass). With water, also turbine, positive displacement, electromagnetic, ultrasonic, vortex and propeller; with hydrocarbons, turbine, positive displacement and ultrasonic.

FLOW RATE

From 50 to 1,100 L/min or kg/min (about 3 to 66 m³/h).

LIQUIDS AND PIPING

Water, hydrocarbons and other liquids · pipe from 12 to 150 mm (½″ to 6″) · up to 1.34 MPa (≈ 13 bar) · from 5 to 40 °C.

ACCURACY

Uncertainty from 0.048 % (mass) and 0.06 % (volumetric): about ±0.6 L per 1,000 L.

WHERE

At your facility · methods based on API MPMS ch. 4.5, 4.8, 11.1 and 12.2.3.

━━

Tanks and tank trucks

✔ ema accreditation V-63

We determine how many liters your tank really holds at each level and give you its calibration table (also called a strapping or gauge table). That way you know exactly how much product you have, receive or deliver.

 

For: storage terminals, service stations, carriers, chemical and food industries.

TANK TRUCKS AND RAIL TANK CARS

From 5,000 to 120,000 L · uncertainty 0.14 % (1.4 L per 1,000 L) · NMX-CH-146-IMNC-2008.

FIXED TANKS: VERTICAL, HORIZONTAL AND IRREGULAR

From 5,000 to 200,000 L, filled through a Coriolis meter · 0.18 % with water (ISO 4269) and 0.21 % with hydrocarbon (API MPMS 2555).

LARGE VERTICAL TANKS, WITH OR WITHOUT DOME

From 200,000 to 2,000,000 L, measuring their geometry with a total station and tape · 0.18 % · API MPMS ch. 2.2A and 2.2G.

WHERE

At your facility.

━━

Gaussmeters, magnets and magnetic traps

✔ PJLA accreditation · ISO/IEC 17025

We check that your gaussmeter measures the magnetic field correctly and that your magnets, magnetic grates and traps keep the strength needed to catch metal particles. A weakened magnet lets contaminants into your product.

 

For: food, pharmaceutical, plastics and recycling industries that use magnetic separation.

GAUSSMETERS

From 1 to 40 G (uncertainty 0.62 %) and from 500 to 10,000 G (0.47 %).

MAGNETS, MAGNETIC GRATES AND TRAPS

From 500 to 10,000 G (uncertainty 0.55 %).

TO GIVE YOU AN IDEA

Earth’s magnetic field is only about 0.5 G and a fridge magnet is around 100 G. 10,000 G equals 1 tesla.

WHERE

At the laboratory (Querétaro, Mexico) or at your facility · IEC 61786-1, ISO 10305-2 and IEC 60404-4, -6 and -8-10.

HOW IT WORKS

From your request to the certificate, in four steps

01

Tell us what you need

Which instrument or tank it is, its range and where it is installed. With that we prepare your quote.

02

We schedule the visit

We agree on the date and what is needed on site: access, available liquid and, if necessary, a brief equipment shutdown.

03

We calibrate

Authorized laboratory staff perform the calibration with standards traceable to CENAM, following the accredited method.

04

You get your certificate

With results, error, uncertainty and the corresponding accreditation symbol, ready for your audits.

ACCREDITATIONS

Credentials you can verify

The laboratory’s standards are calibrated at CENAM. You can confirm the validity of the accreditations at ema.org.mx and pjlabs.com.

EMA · FL-42

Liquid flow

Mexican Accreditation Entity (ema). Scope revision 06, issued September 1, 2026.

EMA · V-63

Volume: tanks and tank trucks

Mexican Accreditation Entity (ema). Scope revision 07, issued September 1, 2026.

PJLA · L26-716

Gaussmeters and magnets

Perry Johnson Laboratory Accreditation, ISO/IEC 17025:2017. Accreditation No. 135790, valid until November 30, 2028. International recognition under ILAC-MRA.

FREQUENTLY ASKED QUESTIONS

What people usually ask us

 

What is an accredited calibration?

It is a calibration performed by a laboratory whose technical competence has been evaluated and recognized by an independent body (in Mexico, ema; internationally, bodies such as PJLA) under ISO/IEC 17025. It is the type of certificate that audits and quality systems usually ask for.

 

What does “uncertainty” mean?

It is the margin within which the true value lies. An uncertainty of 0.06 % means that, for 1,000 liters, the result is reliable within ±0.6 L. The smaller, the better.

 

What is a tank calibration table?

It is the table that converts the liquid level in your tank into liters. Without it, or with an outdated one, your inventory can show significant differences.

 

Do you need to take my equipment away?

Not for flow meters or tanks: they are calibrated at your facility. Gaussmeters and magnets can be calibrated at the laboratory or on site.

 

How often should I calibrate?

Your quality system, the standard that applies to your process or your customer defines it. Many companies do it once a year; if the instrument is hit, repaired or gives odd readings, it is best to do it sooner.

 

 

Ready to calibrate?

Tell us what equipment you have and we will send you a no-obligation quote.

Use of this site implies acceptance of the Terms and Conditions.

Comments or requests: axotek.me@outlook.com

  • WhatsApp
  • Facebook

Designed by AxoTek IRL 2026

bottom of page